Kohler 20kw generator manual
Engine Model CH Phase Single Phase or Three Phase. Built in Mounting Pad Yes. Vent Tube Plug Kit. Battery Heater, V. Carburetor Heater, 40W, V, 20kW. Alternator Weather Cover. Load Shed Kit. Emergency Stop Kit. Technical Documents. Help Us Improve This Site. Remote Monitoring Available Included. Weight lbs. Alternator Type 2-Pole, Rotating Field. Controller RDC2 Controller. Cylinder Arrangement V Dimensions mm x mm x mm 48 in.
Engine Model CH Phase Single Phase. Built in Mounting Pad Yes. Carburetor Heater, 40W, V, 20kW. Vent Tube Plug Kit. See Figure and use the instructions Section 1. Page 19 Connect and turn on the new fuel supply.
Run the generator set and check the operation. Reconnect the generator set engine starting Press the OFF button to shut down the generator battery leads, negative -- lead last. The unit is typically shipped set up for natural gas, with the loose orifice tied near the fuel solenoid valve. Page Electrical Connections 1.
Page Grounding 1. The grounding method The generator set is equipped with a field-connection must comply with NEC and local codes. Connect the terminal block located in the air intake area near the grounding cable to the generator set ground terminal junction box. Page 23 See Figure for terminal block details.
Refer to the a. Route the network cable with other low-voltage terminal block decal shown in Figure for signal wiring for example, the RBUS connections and cable sizes. Also see the wiring communication leads or engine start leads to diagram in Section 3. Page Ac Power Supply 1. The power source must comply with state and local codes. The power to the battery charger and accessories must be backed up by the generator so that power is available at all times.
See Figure Use shielded, connections from the generator set to automatic transfer twisted-pair communication cable to connect P switches and RBUS accessories, including the through P on the transfer switch interface module to Generator Set Terminal Block. See the dimension drawings in Section 3 for location. Check the decal on the generator set for terminal block connections. Engine start leads 3 and 4. See the ATS manual for cable size specifications. Page 27 Maximum length per run, meters ft.
See Section 1. Do not use a load shed kit with a combined interface board. D See Section 1. Page Battery 1. Battery acid can cause severe injury or death. Battery acid is electrically conductive and corrosive. Add g 1 lb. Use a 1. Ensure that the starting battery is fully charged volt group 51 battery with a minimum rating of before placing the battery in service.
The generator set uses a 2. Page Prestart Installation Check 1.